Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging

Mechtenberg M, Grimmelsmann N, Meyer HG, Schneider A (2022)
PLoS ONE 17(10): e0275128.

Zeitschriftenaufsatz | Veröffentlicht | Englisch
 
Download
Es wurden keine Dateien hochgeladen. Nur Publikationsnachweis!
Autor*in
Mechtenberg, Malte; Grimmelsmann, Nils; Meyer, Hanno GerdUniBi; Schneider, Axel
Abstract / Bemerkung
Tendons consist of passive soft tissue with non linear material properties. They play a key role in force transmission from muscle to skeletal structure. The properties of tendons have been extensively examined in vitro. In this work, a non linear model of the distal biceps brachii tendon was parameterized based on measurements of myotendinous junction displacements in vivo at different load forces and elbow angles. The myotendinous junction displacement was extracted from ultrasound B-mode images within an experimental setup which also allowed for the retrieval of the exerted load forces as well as the elbow joint angles. To quantify the myotendinous junction movement based on visual features from ultrasound images, a manual and an automatic method were developed. The performance of both methods was compared. By means of exemplary data from three subjects, reliable fits of the tendon model were achieved. Further, different aspects of the non linear tendon model generated in this way could be reconciled with individual experiments from literature.
Erscheinungsjahr
2022
Zeitschriftentitel
PLoS ONE
Band
17
Ausgabe
10
Art.-Nr.
e0275128
eISSN
1932-6203
Page URI
https://pub.uni-bielefeld.de/record/2966249

Zitieren

Mechtenberg M, Grimmelsmann N, Meyer HG, Schneider A. Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging. PLoS ONE . 2022;17(10): e0275128.
Mechtenberg, M., Grimmelsmann, N., Meyer, H. G., & Schneider, A. (2022). Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging. PLoS ONE , 17(10), e0275128. https://doi.org/10.1371/journal.pone.0275128
Mechtenberg, Malte, Grimmelsmann, Nils, Meyer, Hanno Gerd, and Schneider, Axel. 2022. “Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging”. PLoS ONE 17 (10): e0275128.
Mechtenberg, M., Grimmelsmann, N., Meyer, H. G., and Schneider, A. (2022). Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging. PLoS ONE 17:e0275128.
Mechtenberg, M., et al., 2022. Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging. PLoS ONE , 17(10): e0275128.
M. Mechtenberg, et al., “Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging”, PLoS ONE , vol. 17, 2022, : e0275128.
Mechtenberg, M., Grimmelsmann, N., Meyer, H.G., Schneider, A.: Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging. PLoS ONE . 17, : e0275128 (2022).
Mechtenberg, Malte, Grimmelsmann, Nils, Meyer, Hanno Gerd, and Schneider, Axel. “Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging”. PLoS ONE 17.10 (2022): e0275128.
Export

Markieren/ Markierung löschen
Markierte Publikationen

Open Data PUB

Web of Science

Dieser Datensatz im Web of Science®
Quellen

PMID: 36201491
PubMed | Europe PMC

Suchen in

Google Scholar