Stapes Prosthesis Length: One Size Fits All?

Sudhoff H, Gehl HB, Boga E, Müller S, Wilms K, Mutze S, Todt I (2019)
Audiology and Neurotology 24(1): 1-7.

Zeitschriftenaufsatz | Veröffentlicht | Englisch
 
Download
Es wurden keine Dateien hochgeladen. Nur Publikationsnachweis!
Autor*in
Sudhoff, HolgerUniBi ; Gehl, Hans Björn; Boga, Ercan; Müller, Stefan; Wilms, Katharina; Mutze, Sven; Todt, Ingo
Abstract / Bemerkung
Background: The insertion of the stapes piston into the vestibule provides the physical basis for a successful stapedotomy. In routine clinical practice, two different ways to handle prosthesis length are performed: (1) an individualized measurement of the stapes prosthesis length or (2) a standard prosthesis length for all cases. Objective: The objective of this study was to compare both ways of handling prosthesis length and the effect of these methods on insertional prosthesis depth. Material and Method: We retrospectively evaluated 39 patients after performing a stapedotomy for radiologically estimated vestibular stapes prosthesis insertion depth. The individual measured length data were hypothetically changed to a standard length of 4.75, 5, 5.25, and 5.5 mm, and the insertion depths were compared. Results: The individually measured prosthesis lengths led to an insertion depth between 0.2 and 1.6 mm (mean 0.74 mm). The ratio of insertion depth/vestibular depth was between 8 and 59.1% (mean 26.6%). The different assumed standard lengths led to different rates of the vestibulum positions and possible bony contacts at the vestibulum floor. Conclusion: The individual measurement led to a zero rate of the vestibulum positions of stapes prosthesis pistons with a low insertion depth/vestibular depth ratio.
Erscheinungsjahr
2019
Zeitschriftentitel
Audiology and Neurotology
Band
24
Ausgabe
1
Seite(n)
1-7
ISSN
1420-3030
eISSN
1421-9700
Page URI
https://pub.uni-bielefeld.de/record/2951837

Zitieren

Sudhoff H, Gehl HB, Boga E, et al. Stapes Prosthesis Length: One Size Fits All? Audiology and Neurotology. 2019;24(1):1-7.
Sudhoff, H., Gehl, H. B., Boga, E., Müller, S., Wilms, K., Mutze, S., & Todt, I. (2019). Stapes Prosthesis Length: One Size Fits All? Audiology and Neurotology, 24(1), 1-7. https://doi.org/10.1159/000494915
Sudhoff, Holger, Gehl, Hans Björn, Boga, Ercan, Müller, Stefan, Wilms, Katharina, Mutze, Sven, and Todt, Ingo. 2019. “Stapes Prosthesis Length: One Size Fits All?”. Audiology and Neurotology 24 (1): 1-7.
Sudhoff, H., Gehl, H. B., Boga, E., Müller, S., Wilms, K., Mutze, S., and Todt, I. (2019). Stapes Prosthesis Length: One Size Fits All? Audiology and Neurotology 24, 1-7.
Sudhoff, H., et al., 2019. Stapes Prosthesis Length: One Size Fits All? Audiology and Neurotology, 24(1), p 1-7.
H. Sudhoff, et al., “Stapes Prosthesis Length: One Size Fits All?”, Audiology and Neurotology, vol. 24, 2019, pp. 1-7.
Sudhoff, H., Gehl, H.B., Boga, E., Müller, S., Wilms, K., Mutze, S., Todt, I.: Stapes Prosthesis Length: One Size Fits All? Audiology and Neurotology. 24, 1-7 (2019).
Sudhoff, Holger, Gehl, Hans Björn, Boga, Ercan, Müller, Stefan, Wilms, Katharina, Mutze, Sven, and Todt, Ingo. “Stapes Prosthesis Length: One Size Fits All?”. Audiology and Neurotology 24.1 (2019): 1-7.
Export

Markieren/ Markierung löschen
Markierte Publikationen

Open Data PUB

Web of Science

Dieser Datensatz im Web of Science®
Quellen

PMID: 30783032
PubMed | Europe PMC

Suchen in

Google Scholar