The Pull-Back Technique for the 532 Slim Modiolar Electrode

Riemann C, Sudhoff H, Todt I (2019)
BioMed Research International 2019: 6917084 .

Zeitschriftenaufsatz | Veröffentlicht | Englisch
 
Download
Es wurden keine Dateien hochgeladen. Nur Publikationsnachweis!
Autor*in
Riemann, C.; Sudhoff, HolgerUniBi ; Todt, I.
Abstract / Bemerkung
Introduction. The distance between the modiolus and the electrode array is one factor that has become the focus of many discussions and studies. Positioning the electrode array closer to the spiral ganglion with the goal of reducing the current spread has been shown to improve hearing outcomes. The perimodiolar electrode arrays can be complemented with a surgical manoeuvre called the pull-back technique. This study focuses its attention on the recently developed 532 slim modiolar electrode. Objective. To investigate the intracochlear movements and pull-back technique for the 532 slim modiolar electrode. Material and Methods. A decapping procedure of the cochlea was performed on 5 temporal bones. The electrode array was inserted, and the intracochlear movements were microscopically examined and digitally captured. Three situations were analysed: the initial insertion, the overinsertion, and the pull-back position. The position of the three white markers of the electrode array in relation to the round window (RW) was evaluated while performing these three actions. Results. The initial insertion achieved an acceptable perimodiolar position of the electrode array, but a gap was still observed between the mid-portion of the array and the modiolus (the first white marker was seen in the RW). When we inserted the electrode more deeply, the mid-portion of the array was pushed away from the modiolus (the second and third white markers were seen in the RW). After applying the pull-back technique, the gap observed during the initial insertion disappeared, resulting in an optimal perimodiolar position (the first white marker was once again visible in the RW). Conclusion. This temporal bone study demonstrated that when applying the pull-back technique for the 532 slim modiolar electrode, a closer proximity to the modiolus was achieved when the first white marker of the electrode array was visible in the round window.
Erscheinungsjahr
2019
Zeitschriftentitel
BioMed Research International
Band
2019
Art.-Nr.
6917084
ISSN
2314-6133
eISSN
2314-6141
Page URI
https://pub.uni-bielefeld.de/record/2951832

Zitieren

Riemann C, Sudhoff H, Todt I. The Pull-Back Technique for the 532 Slim Modiolar Electrode. BioMed Research International. 2019;2019: 6917084 .
Riemann, C., Sudhoff, H., & Todt, I. (2019). The Pull-Back Technique for the 532 Slim Modiolar Electrode. BioMed Research International, 2019, 6917084 . https://doi.org/10.1155/2019/6917084
Riemann, C., Sudhoff, Holger, and Todt, I. 2019. “The Pull-Back Technique for the 532 Slim Modiolar Electrode”. BioMed Research International 2019: 6917084 .
Riemann, C., Sudhoff, H., and Todt, I. (2019). The Pull-Back Technique for the 532 Slim Modiolar Electrode. BioMed Research International 2019:6917084 .
Riemann, C., Sudhoff, H., & Todt, I., 2019. The Pull-Back Technique for the 532 Slim Modiolar Electrode. BioMed Research International, 2019: 6917084 .
C. Riemann, H. Sudhoff, and I. Todt, “The Pull-Back Technique for the 532 Slim Modiolar Electrode”, BioMed Research International, vol. 2019, 2019, : 6917084 .
Riemann, C., Sudhoff, H., Todt, I.: The Pull-Back Technique for the 532 Slim Modiolar Electrode. BioMed Research International. 2019, : 6917084 (2019).
Riemann, C., Sudhoff, Holger, and Todt, I. “The Pull-Back Technique for the 532 Slim Modiolar Electrode”. BioMed Research International 2019 (2019): 6917084 .

Zitationen in Europe PMC

Daten bereitgestellt von Europe PubMed Central.

References

Daten bereitgestellt von Europe PubMed Central.

Export

Markieren/ Markierung löschen
Markierte Publikationen

Open Data PUB

Web of Science

Dieser Datensatz im Web of Science®
Quellen

PMID: 31240221
PubMed | Europe PMC

Suchen in

Google Scholar