Picosecond optical parametric oscillators (OPOs) with broad wavelength tunability are frequently used as light sources in hyperspectral coherent Raman scattering (CRS) microscopy. We investigate how changes in the pulse length during OPO wavelength tuning of the pump beam affect hyperspectral CRS imaging. We find that significant distortions of the resulting CRS spectra occur if the OPO is operated without monitoring pulse length variations. By utilizing a custom-written MATLAB based control program to counteract changes in pulse length, normalized and reproducible data sets can be acquired. We demonstrate this by comparing hyperspectral data obtained from pure substances, as well as relevant biological specimens.
Erscheinungsjahr
2018
Zeitschriftentitel
Optics Express
Band
26
Ausgabe
22
Seite(n)
28312-28322
ISSN
1094-4087
eISSN
1094-4087
Finanzierungs-Informationen
Open-Access-Publikationskosten wurden durch die Deutsche Forschungsgemeinschaft und die Universität Bielefeld gefördert.
Page URI
https://pub.uni-bielefeld.de/record/2931609
Zitieren
Pilger C, Hachmeister H, Greife P, Weiss A, Wiebusch G, Huser T. Pulse length variation causing spectral distortions in OPO-based hyperspectral coherent Raman scattering microscopy. Optics Express. 2018;26(22):28312-28322.
Pilger, C., Hachmeister, H., Greife, P., Weiss, A., Wiebusch, G., & Huser, T. (2018). Pulse length variation causing spectral distortions in OPO-based hyperspectral coherent Raman scattering microscopy. Optics Express, 26(22), 28312-28322. https://doi.org/10.1364/oe.26.028312
Pilger, Christian, Hachmeister, Henning, Greife, Paul, Weiss, Alexa, Wiebusch, Gerd, and Huser, Thomas. 2018. “Pulse length variation causing spectral distortions in OPO-based hyperspectral coherent Raman scattering microscopy”. Optics Express 26 (22): 28312-28322.
Pilger, C., Hachmeister, H., Greife, P., Weiss, A., Wiebusch, G., and Huser, T. (2018). Pulse length variation causing spectral distortions in OPO-based hyperspectral coherent Raman scattering microscopy. Optics Express 26, 28312-28322.
Pilger, C., et al., 2018. Pulse length variation causing spectral distortions in OPO-based hyperspectral coherent Raman scattering microscopy. Optics Express, 26(22), p 28312-28322.
C. Pilger, et al., “Pulse length variation causing spectral distortions in OPO-based hyperspectral coherent Raman scattering microscopy”, Optics Express, vol. 26, 2018, pp. 28312-28322.
Pilger, C., Hachmeister, H., Greife, P., Weiss, A., Wiebusch, G., Huser, T.: Pulse length variation causing spectral distortions in OPO-based hyperspectral coherent Raman scattering microscopy. Optics Express. 26, 28312-28322 (2018).
Pilger, Christian, Hachmeister, Henning, Greife, Paul, Weiss, Alexa, Wiebusch, Gerd, and Huser, Thomas. “Pulse length variation causing spectral distortions in OPO-based hyperspectral coherent Raman scattering microscopy”. Optics Express 26.22 (2018): 28312-28322.
Alle Dateien verfügbar unter der/den folgenden Lizenz(en):
Copyright Statement:
Dieses Objekt ist durch das Urheberrecht und/oder verwandte Schutzrechte geschützt. [...]
Volltext(e)
Name
oe-26-22-28312.huser.pdf
6.12 MB
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-06T09:19:02Z
MD5 Prüfsumme
347d02582a44c0a309e2dc04df6e9c10
Daten bereitgestellt von European Bioinformatics Institute (EBI)
Zitationen in Europe PMC
Daten bereitgestellt von Europe PubMed Central.
References
Daten bereitgestellt von Europe PubMed Central.
Export
Markieren/ Markierung löschen
Markierte Publikationen
Web of Science
Dieser Datensatz im Web of Science®Quellen
PMID: 30470005
PubMed | Europe PMC
Suchen in