Supplementary Material for "Using Sonification to detect weak cross-correlations in coupled excitable systems"
Baier G, Müller M, Hermann T (2005)
Bielefeld University.
Datenpublikation
Creator
Baier, Gerold;
Müller, Markus;
Hermann, ThomasUniBi
Einrichtung
Abstract / Bemerkung
We study cross-correlations in irregularly spiking systems. A single system displays spiking sequences that resemble a stochastic (Poisson) process. Linear coupling between two systems leaves the inter-spike interval distribution qualitatively unchanged but induces cross-correlations between the units. For strong coupling this leads to synchronization as expected but for weak coupling, both a good statistic and sonification reveal the presence of ``motifs'', preferred short firing sequences which are due to the deterministic spiking mechanism. We argue that the use of sonification for time series analysis is superior in the case where intrinsic non-stationarity of an experiment cannot be ruled out.
#### Audifications
S1a: compression factor 2
S1b: compression factor 6
S1c: compression factor 50
#### Amplitude Modulation
S2a: rate 0.1
S2b: rate 0.2
S2c: rate 1
#### Event-based rhythms
S3a: r=1 D=0
S3b: r=1 D=0.00125
S3c: r=5 D=0
S3d: r=5 D=0.00125
#### Timbre mapping
S4a: 20sec D=0
S4d: 20sec D=0.00125
S4b: 60sec D=0
S4e: 60sec D=0.00125
S4c: 240sec D=0
S4f: 240sec D=0.00125
#### Sonifications for coupling drift
S5a: D=0..0.005,20sec rhythm
S5b: D=0..0.005,20sec pitch deviation
S5c: D=0..0.005,20sec timbre
#### Timbre Sonifications of Coupling drift
S6a: 20sec, D=0..0.00125
S6b: 30sec, D=0..0.00125
S6c 20sec, D=0..0.005
S6d 30sec, D=0..0.005
Erscheinungsjahr
2005
Copyright und Lizenzen
Page URI
https://pub.uni-bielefeld.de/record/2700964
Zitieren
Baier G, Müller M, Hermann T. Supplementary Material for "Using Sonification to detect weak cross-correlations in coupled excitable systems". Bielefeld University; 2005.
Baier, G., Müller, M., & Hermann, T. (2005). Supplementary Material for "Using Sonification to detect weak cross-correlations in coupled excitable systems". Bielefeld University. doi:10.4119/unibi/2700964
Baier, Gerold, Müller, Markus, and Hermann, Thomas. 2005. Supplementary Material for "Using Sonification to detect weak cross-correlations in coupled excitable systems". Bielefeld University.
Baier, G., Müller, M., and Hermann, T. (2005). Supplementary Material for "Using Sonification to detect weak cross-correlations in coupled excitable systems". Bielefeld University.
Baier, G., Müller, M., & Hermann, T., 2005. Supplementary Material for "Using Sonification to detect weak cross-correlations in coupled excitable systems", Bielefeld University.
G. Baier, M. Müller, and T. Hermann, Supplementary Material for "Using Sonification to detect weak cross-correlations in coupled excitable systems", Bielefeld University, 2005.
Baier, G., Müller, M., Hermann, T.: Supplementary Material for "Using Sonification to detect weak cross-correlations in coupled excitable systems". Bielefeld University (2005).
Baier, Gerold, Müller, Markus, and Hermann, Thomas. Supplementary Material for "Using Sonification to detect weak cross-correlations in coupled excitable systems". Bielefeld University, 2005.
Alle Dateien verfügbar unter der/den folgenden Lizenz(en):
Open Database License (ODbL) v1.0:
Volltext(e)
Name
Beschreibung
rate 1
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
d6aaae705df74e32824ef7a36cf4f362
Name
Beschreibung
r=1 D=0
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
0882093987dc864337f4b385df98cf8a
Name
Beschreibung
r=5 D=0
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
04a05e5bac79d868877a53345dc8eee7
Name
Beschreibung
r=5 D=0.00125
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
31f3b28cddce70c31ead1c6c2a5c8a26
Name
Beschreibung
r=1 D=0.00125
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
b7d4f721a5ac251368ee96e8571d214f
Name
Beschreibung
20sec D=0
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
3bd07e7c73ee1d822b256f46420dd596
Name
Beschreibung
rate 0.1
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
bc0486f1f7d713a6a6ccb95bd3abc34d
Name
Beschreibung
compression factor 6
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
30b2cc7b0634e37b229f63a21de17898
Name
Beschreibung
compression factor 50
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
cf087191a8dbe69f08e2c82dd2dc85a6
Name
Beschreibung
compression factor 2
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
50a1628776adda6c1f0e7f85ec5094a4
Name
Beschreibung
rate 0.2
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
869f375f67de0658e1c038650247ea75
Name
Beschreibung
60sec D=0
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
85d7406a50635dab8dd82b4d02598b0b
Name
Beschreibung
20sec, D=0..0.005
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
fa3d61aca5a41c651a3bd89def803c1a
Name
Beschreibung
240sec D=0
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
f82187062cae20ad711762dee4af99b1
Name
Beschreibung
30sec, D=0..0.005
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
1c9f00912cea4cc03fe7d36012709e52
Name
Beschreibung
30sec, D=0..0.00125
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
74f441eeb621237539714fc737f21f20
Name
Beschreibung
20sec D=0.00125
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
97d9f0264ba1fbce5aa40bcb81481d26
Name
Beschreibung
60sec D=0.00125
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
333487911cf1aaa26a1861ca2178ef6d
Name
Beschreibung
240sec D=0.00125
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
2088baca52f30e875e3d8ec350e9b84d
Name
Beschreibung
D=0..0.005,20sec rhythm
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
12da6e19e48a1eca553d4014e7bdfed0
Name
Beschreibung
D=0..0.005,20sec pitch deviation
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
d6f94ad92080cc016f50a77cb5667dd0
Name
Beschreibung
D=0..0.005,20sec timbre
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
9fe7223ee792df2dc91e7aa1ba7c92fa
Name
Beschreibung
20sec, D=0..0.00125
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-12T10:00:49Z
MD5 Prüfsumme
4917797311799600ac7c53cae1a6e0e6
Material in PUB:
Wird zitiert von
Using sonification to detect weak cross-correlations in coupled excitable systems
Baier G, Hermann T, Lara OM, Müller M (2005)
In: Proceedings of the International Conference on Auditory Display. Brazil E (Ed); Limerick, Ireland: International Community for Auditory Display: 312-315.
Baier G, Hermann T, Lara OM, Müller M (2005)
In: Proceedings of the International Conference on Auditory Display. Brazil E (Ed); Limerick, Ireland: International Community for Auditory Display: 312-315.