Nanoscale modification of conducting lines with a scanning force microscope

Rank R, Brückl H, Kretz J, Monch I, Reiss G (1997)
Vacuum 48(5): 467-472.

Zeitschriftenaufsatz | Veröffentlicht | Englisch
 
Download
Es wurden keine Dateien hochgeladen. Nur Publikationsnachweis!
Autor*in
Rank, R; Brückl, Hubert; Kretz, J; Monch, I; Reiss, GünterUniBi
Abstract / Bemerkung
In the presented work the controlled mechanical modification of conducting lines on a nanometer scale by a scanning force microscope will be demonstrated. To achieve the high loads necessary for the modification of the lines, noncontact cantilevers and home made supertips have been used in contact mode. Aluminium and an alloy of gold-palladium have been used as materials for studying the influence of the different parameter as well as the mechanical properties of the thin films on the modification process. Qualitative conclusions will be made. The process of modification is monitored and controlled for the first time by an in situ measurement of the electric resistance of the modified conducting line. A Wheatstone bridge and lock-in technique have been used to observe the change in the resistance. (C) 1997 Elsevier Science Ltd.
Erscheinungsjahr
1997
Zeitschriftentitel
Vacuum
Band
48
Ausgabe
5
Seite(n)
467-472
ISSN
0042-207X
Page URI
https://pub.uni-bielefeld.de/record/2353097

Zitieren

Rank R, Brückl H, Kretz J, Monch I, Reiss G. Nanoscale modification of conducting lines with a scanning force microscope. Vacuum. 1997;48(5):467-472.
Rank, R., Brückl, H., Kretz, J., Monch, I., & Reiss, G. (1997). Nanoscale modification of conducting lines with a scanning force microscope. Vacuum, 48(5), 467-472. https://doi.org/10.1016/S0042-207X(96)00308-9
Rank, R, Brückl, Hubert, Kretz, J, Monch, I, and Reiss, Günter. 1997. “Nanoscale modification of conducting lines with a scanning force microscope”. Vacuum 48 (5): 467-472.
Rank, R., Brückl, H., Kretz, J., Monch, I., and Reiss, G. (1997). Nanoscale modification of conducting lines with a scanning force microscope. Vacuum 48, 467-472.
Rank, R., et al., 1997. Nanoscale modification of conducting lines with a scanning force microscope. Vacuum, 48(5), p 467-472.
R. Rank, et al., “Nanoscale modification of conducting lines with a scanning force microscope”, Vacuum, vol. 48, 1997, pp. 467-472.
Rank, R., Brückl, H., Kretz, J., Monch, I., Reiss, G.: Nanoscale modification of conducting lines with a scanning force microscope. Vacuum. 48, 467-472 (1997).
Rank, R, Brückl, Hubert, Kretz, J, Monch, I, and Reiss, Günter. “Nanoscale modification of conducting lines with a scanning force microscope”. Vacuum 48.5 (1997): 467-472.
Export

Markieren/ Markierung löschen
Markierte Publikationen

Open Data PUB

Web of Science

Dieser Datensatz im Web of Science®
Suchen in

Google Scholar