Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification
Büntemeyer H, Tebbe H, Lütkemeyer D, Lehmann J (1994)
Journal of Chromatography, B: Biomedical Sciences and Applications 662(2): 209-216.
Zeitschriftenaufsatz
| Veröffentlicht | Englisch
Download
Autor*in
Büntemeyer, HeinoUniBi;
Tebbe, H.;
Lütkemeyer, DirkUniBi;
Lehmann, Jürgen
Einrichtung
Abstract / Bemerkung
For monitoring of recombinant human antithrombin III during cell culture processes and subsequent purification steps a rapid method for quantitative determination was developed. The need for the introduction of this rapid method came from the limited availability of a quantitative enzyme-linked immunosorbent assay (ELISA) and the very time-consuming ELISA procedure. The developed method is based on reversed-phase high-performance liquid chromatography using a C 4 column. The separation by gradient elution using water and acetonitrile takes less than 20 min even when complex samples, such as serum containing cell culture samples, have to be analyzed. Automation and a high sample throughput are possible with this reliable method. If necessary, insulin, transferrin and albumin can also be quantified with minor changes of the elution profile.
Erscheinungsjahr
1994
Zeitschriftentitel
Journal of Chromatography, B: Biomedical Sciences and Applications
Band
662
Ausgabe
2
Seite(n)
209-216
ISSN
0378-4347
Page URI
https://pub.uni-bielefeld.de/record/1782395
Zitieren
Büntemeyer H, Tebbe H, Lütkemeyer D, Lehmann J. Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications. 1994;662(2):209-216.
Büntemeyer, H., Tebbe, H., Lütkemeyer, D., & Lehmann, J. (1994). Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications, 662(2), 209-216. https://doi.org/10.1016/0378-4347(94)00266-5
Büntemeyer, Heino, Tebbe, H., Lütkemeyer, Dirk, and Lehmann, Jürgen. 1994. “Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification”. Journal of Chromatography, B: Biomedical Sciences and Applications 662 (2): 209-216.
Büntemeyer, H., Tebbe, H., Lütkemeyer, D., and Lehmann, J. (1994). Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications 662, 209-216.
Büntemeyer, H., et al., 1994. Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications, 662(2), p 209-216.
H. Büntemeyer, et al., “Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification”, Journal of Chromatography, B: Biomedical Sciences and Applications, vol. 662, 1994, pp. 209-216.
Büntemeyer, H., Tebbe, H., Lütkemeyer, D., Lehmann, J.: Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications. 662, 209-216 (1994).
Büntemeyer, Heino, Tebbe, H., Lütkemeyer, Dirk, and Lehmann, Jürgen. “Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification”. Journal of Chromatography, B: Biomedical Sciences and Applications 662.2 (1994): 209-216.
Alle Dateien verfügbar unter der/den folgenden Lizenz(en):
Copyright Statement:
Dieses Objekt ist durch das Urheberrecht und/oder verwandte Schutzrechte geschützt. [...]
Volltext(e)
Name
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-06T08:48:46Z
MD5 Prüfsumme
b90efde7201af7e1bf95810cb563f25e
Daten bereitgestellt von European Bioinformatics Institute (EBI)
4 Zitationen in Europe PMC
Daten bereitgestellt von Europe PubMed Central.
Efficient single step chromatographic purification of recombinant human antithrombin (rhAT) from Saccharomyces cerevisiae.
Mallu MR, Vemula S, Ronda SR., 3 Biotech 6(1), 2016
PMID: 28330182
Mallu MR, Vemula S, Ronda SR., 3 Biotech 6(1), 2016
PMID: 28330182
Recovery of antithrombin III from milk by expanded bed chromatography.
Ozyurt S, Kirdar B, Ulgen KO., J Chromatogr A 944(1-2), 2002
PMID: 11831754
Ozyurt S, Kirdar B, Ulgen KO., J Chromatogr A 944(1-2), 2002
PMID: 11831754
Rapid reversed-phase high-performance liquid chromatography method for quantitation, at high pH, of the recombinant apolipoprotein A-IMilano in Escherichia coli fermentation broth.
Mulugeta E, Carnö S, Becker S, Hagman A, Mascher E., J Chromatogr A 798(1-2), 1998
PMID: 9542129
Mulugeta E, Carnö S, Becker S, Hagman A, Mascher E., J Chromatogr A 798(1-2), 1998
PMID: 9542129
Production of recombinant human antithrombin III on 20-L bioreactor scale: correlation of supernatant neuraminidase activity, desialylation, and decrease of biological activity of recombinant glycoprotein.
Munzert E, Heidemann R, Büntemeyer H, Lehmann J, Müthing J., Biotechnol Bioeng 56(4), 1997
PMID: 18642246
Munzert E, Heidemann R, Büntemeyer H, Lehmann J, Müthing J., Biotechnol Bioeng 56(4), 1997
PMID: 18642246
References
Daten bereitgestellt von Europe PubMed Central.
Export
Markieren/ Markierung löschen
Markierte Publikationen
Web of Science
Dieser Datensatz im Web of Science®Quellen
PMID: 7719477
PubMed | Europe PMC
Suchen in