Multimass thermal desorption spectroscopy as a monitoring device for chemical reaction products
Zagatta G, Müller H, Böwering N, Heinzmann U (1994)
Review of Scientific Instruments 65(2): 359-362.
Zeitschriftenaufsatz
| Veröffentlicht | Englisch
Download
Autor*in
Zagatta, Gunther;
Müller, H.;
Böwering, N.;
Heinzmann, UlrichUniBi
Abstract / Bemerkung
To observe the products of surface reaction mechanisms we combined a standard quadrupole mass spectrometer featuring high-speed scanning options with fast data acquisition and a computer-controlled sample heating system. This combination served to obtain a general view (like a 'fingerprint') of the reaction occurring on a Pt(100) crystal upon heating the adsorbate covered surface, as well as to allow for a detailed analysis of the gas compounds leaving the surface within a single measurement. The method is denoted by multimass thermal desorption spectroscopy (MTDS). The MTDS device is capable of recording 850 amu/s providing up to 15 complete mass spectra per second of 50 amu width while heating the surface linearly. The data contain the ion currents of both the reaction products and their fractions (cracking patterns) generated in the spectrometer. Thus it is possible to distinguish between gas species with equal mass numbers by subsequent numerical evaluation.
Erscheinungsjahr
1994
Zeitschriftentitel
Review of Scientific Instruments
Band
65
Ausgabe
2
Seite(n)
359-362
ISSN
0034-6748
Page URI
https://pub.uni-bielefeld.de/record/1780442
Zitieren
Zagatta G, Müller H, Böwering N, Heinzmann U. Multimass thermal desorption spectroscopy as a monitoring device for chemical reaction products. Review of Scientific Instruments. 1994;65(2):359-362.
Zagatta, G., Müller, H., Böwering, N., & Heinzmann, U. (1994). Multimass thermal desorption spectroscopy as a monitoring device for chemical reaction products. Review of Scientific Instruments, 65(2), 359-362. https://doi.org/10.1063/1.1145196
Zagatta, Gunther, Müller, H., Böwering, N., and Heinzmann, Ulrich. 1994. “Multimass thermal desorption spectroscopy as a monitoring device for chemical reaction products”. Review of Scientific Instruments 65 (2): 359-362.
Zagatta, G., Müller, H., Böwering, N., and Heinzmann, U. (1994). Multimass thermal desorption spectroscopy as a monitoring device for chemical reaction products. Review of Scientific Instruments 65, 359-362.
Zagatta, G., et al., 1994. Multimass thermal desorption spectroscopy as a monitoring device for chemical reaction products. Review of Scientific Instruments, 65(2), p 359-362.
G. Zagatta, et al., “Multimass thermal desorption spectroscopy as a monitoring device for chemical reaction products”, Review of Scientific Instruments, vol. 65, 1994, pp. 359-362.
Zagatta, G., Müller, H., Böwering, N., Heinzmann, U.: Multimass thermal desorption spectroscopy as a monitoring device for chemical reaction products. Review of Scientific Instruments. 65, 359-362 (1994).
Zagatta, Gunther, Müller, H., Böwering, N., and Heinzmann, Ulrich. “Multimass thermal desorption spectroscopy as a monitoring device for chemical reaction products”. Review of Scientific Instruments 65.2 (1994): 359-362.
Alle Dateien verfügbar unter der/den folgenden Lizenz(en):
Copyright Statement:
Dieses Objekt ist durch das Urheberrecht und/oder verwandte Schutzrechte geschützt. [...]
Volltext(e)
Name
Access Level
Open Access
Zuletzt Hochgeladen
2019-09-06T08:48:32Z
MD5 Prüfsumme
b409dbd3899ae72d57738244621a00b9
Export
Markieren/ Markierung löschen
Markierte Publikationen
Web of Science
Dieser Datensatz im Web of Science®Suchen in