Which bosonic loop corrections are tested in electroweak precision measurements?
Dittmaier S, Schildknecht D, Weiglein G (1996)
ACTA PHYSICA POLONICA B 27(10): 2507-2524.
Konferenzbeitrag
| Veröffentlicht | Englisch
Download
Es wurden keine Dateien hochgeladen. Nur Publikationsnachweis!
Autor*in
Dittmaier, S;
Schildknecht, DieterUniBi;
Weiglein, G
Abstract / Bemerkung
The nature of the electroweak bosonic loop corrections to which current precision experiments are sensitive is explored. The set of effective parameters Delta x, Delta y, and epsilon, which quantify SU(2) violation in an effective Lagrangian, is shown to be particularly useful for this purpose. The standard bosonic corrections are sizable only in the parameter Delta y, while Delta x and epsilon are sufficiently well approximated by the pure fermion-loop prediction. By analyzing the contributions to Delta y it is shown that the bosonic loop corrections resolved by the present precision data are induced by the change in energy scale between the low-energy process muon decay and the energy scale of the LEP1 observables. If the (theoretical value of the) leptonic width of the W boson is used as input parameter instead of the Fermi constant G(mu), no further bosonic loop corrections are necessary for compatibility between theory and experiment.
Erscheinungsjahr
1996
Serien- oder Zeitschriftentitel
ACTA PHYSICA POLONICA B
Band
27
Ausgabe
10
Seite(n)
2507-2524
ISSN
0587-4254
Page URI
https://pub.uni-bielefeld.de/record/1628623
Zitieren
Dittmaier S, Schildknecht D, Weiglein G. Which bosonic loop corrections are tested in electroweak precision measurements? ACTA PHYSICA POLONICA B. 1996;27(10):2507-2524.
Dittmaier, S., Schildknecht, D., & Weiglein, G. (1996). Which bosonic loop corrections are tested in electroweak precision measurements? ACTA PHYSICA POLONICA B, 27(10), 2507-2524.
Dittmaier, S, Schildknecht, Dieter, and Weiglein, G. 1996. “Which bosonic loop corrections are tested in electroweak precision measurements?”, ACTA PHYSICA POLONICA B, 27 (10): 2507-2524.
Dittmaier, S., Schildknecht, D., and Weiglein, G. (1996). Which bosonic loop corrections are tested in electroweak precision measurements? ACTA PHYSICA POLONICA B 27, 2507-2524.
Dittmaier, S., Schildknecht, D., & Weiglein, G., 1996. Which bosonic loop corrections are tested in electroweak precision measurements? ACTA PHYSICA POLONICA B, 27(10), p 2507-2524.
S. Dittmaier, D. Schildknecht, and G. Weiglein, “Which bosonic loop corrections are tested in electroweak precision measurements?”, ACTA PHYSICA POLONICA B, vol. 27, 1996, pp. 2507-2524.
Dittmaier, S., Schildknecht, D., Weiglein, G.: Which bosonic loop corrections are tested in electroweak precision measurements? ACTA PHYSICA POLONICA B. 27, 2507-2524 (1996).
Dittmaier, S, Schildknecht, Dieter, and Weiglein, G. “Which bosonic loop corrections are tested in electroweak precision measurements?”. ACTA PHYSICA POLONICA B 27.10 (1996): 2507-2524.
Export
Markieren/ Markierung löschen
Markierte Publikationen
Web of Science
Dieser Datensatz im Web of Science®Suchen in