The COMPASS RICH-1 read-out system
Baum G, Birsa R, Bradamante F, Bressan A, Chapiro A, Cicuttin A, Ciliberti P, Colavita A, Costa S, Crespo M, Cristaudo P, et al. (2003)
In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Nucl.Instrum.Meth. A, 502(1). Elsevier Science BV: 246-250.
Konferenzbeitrag
| Veröffentlicht | Englisch
Download
Es wurden keine Dateien hochgeladen. Nur Publikationsnachweis!
Autor*in
Baum, GünterUniBi;
Birsa, R;
Bradamante, F;
Bressan, A;
Chapiro, A;
Cicuttin, A;
Ciliberti, P;
Colavita, A;
Costa, S;
Crespo, M;
Cristaudo, P;
Dalla Torre, S
Alle
Alle
Einrichtung
Abstract / Bemerkung
This paper describes the reconfigurable read-out system for the 82944 RICH-1 channels of the COMPASS experiment (NA58) at CERN. The system is based on 192 identical large front-end boards (BORA board). BORA was designed for acquiring, digitizing, threshold subtracting and transmitting event data. The overall operation of the board is controlled and supervised by a DSP tightly interacting with an FPGA that acts as a parallel co-processor. The DSP allows characterizing each analog channel by locally calculating noise and pedestal. Each BORA communicates with the outside world through two optical fibers and through a dedicated DSP network. One optical fiber is used to receive event triggers, and the other one is used to transmit event data to subsequent processing stages of the acquisition system. The DSP network allows reconfiguring and reprogramming the DSPs and FPGAs as well as acquiring sample events to visualize the overall operation of the system. The whole RICH has eight DSP networks working in parallel. These networks are handled by DOLINA. a PC resident multiprocessor board containing eight DSPs. Each network is formed by 24 BORA DSPs and I DOLINA DSP. The read-out system can steadily work up to a trigger rate of 75 kHz with maximum pixel occupancy of 20%, reaching a transmission data rate of 5.13 Gbytes/s. (C) 2003 Elsevier Science B.V. All rights reserved.
Stichworte
data acquisition;
RICH detector;
DSP;
FPGA
Erscheinungsjahr
2003
Titel des Konferenzbandes
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Serien- oder Zeitschriftentitel
Nucl.Instrum.Meth. A
Band
502
Ausgabe
1
Seite(n)
246-250
ISSN
0168-9002
Page URI
https://pub.uni-bielefeld.de/record/1611555
Zitieren
Baum G, Birsa R, Bradamante F, et al. The COMPASS RICH-1 read-out system. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Nucl.Instrum.Meth. A. Vol 502. Elsevier Science BV; 2003: 246-250.
Baum, G., Birsa, R., Bradamante, F., Bressan, A., Chapiro, A., Cicuttin, A., Ciliberti, P., et al. (2003). The COMPASS RICH-1 read-out system. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Nucl.Instrum.Meth. A, 502, 246-250. Elsevier Science BV. https://doi.org/10.1016/S0168-9002(03)00282-1
Baum, Günter, Birsa, R, Bradamante, F, Bressan, A, Chapiro, A, Cicuttin, A, Ciliberti, P, et al. 2003. “The COMPASS RICH-1 read-out system”. In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 502:246-250. Nucl.Instrum.Meth. A. Elsevier Science BV.
Baum, G., Birsa, R., Bradamante, F., Bressan, A., Chapiro, A., Cicuttin, A., Ciliberti, P., Colavita, A., Costa, S., Crespo, M., et al. (2003). “The COMPASS RICH-1 read-out system” in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Nucl.Instrum.Meth. A, vol. 502, (Elsevier Science BV), 246-250.
Baum, G., et al., 2003. The COMPASS RICH-1 read-out system. In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Nucl.Instrum.Meth. A. no.502 Elsevier Science BV, pp. 246-250.
G. Baum, et al., “The COMPASS RICH-1 read-out system”, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Nucl.Instrum.Meth. A, vol. 502, Elsevier Science BV, 2003, pp.246-250.
Baum, G., Birsa, R., Bradamante, F., Bressan, A., Chapiro, A., Cicuttin, A., Ciliberti, P., Colavita, A., Costa, S., Crespo, M., Cristaudo, P., Dalla Torre, S., Diaz, V., Fauland, P., Fratnik, F., Giorgi, M., Gobbo, B., Ijaduola, R., Kalinnikov, V., Lamanna, M., Martin, A., Menon, G., Pagano, P., Schiavon, P., Tessarotto, F., Zanetti, A.: The COMPASS RICH-1 read-out system. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Nucl.Instrum.Meth. A. 502, p. 246-250. Elsevier Science BV (2003).
Baum, Günter, Birsa, R, Bradamante, F, Bressan, A, Chapiro, A, Cicuttin, A, Ciliberti, P, Colavita, A, Costa, S, Crespo, M, Cristaudo, P, Dalla Torre, S, Diaz, V, Fauland, P, Fratnik, F, Giorgi, M, Gobbo, B, Ijaduola, R, Kalinnikov, V, Lamanna, M, Martin, A, Menon, G, Pagano, P, Schiavon, P, Tessarotto, F, and Zanetti, A. “The COMPASS RICH-1 read-out system”. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Elsevier Science BV, 2003.Vol. 502. Nucl.Instrum.Meth. A. 246-250.
Export
Markieren/ Markierung löschen
Markierte Publikationen
Web of Science
Dieser Datensatz im Web of Science®Quellen
Inspire: 619250
Suchen in