Performance of the COMPASS polarized target dilution refrigerator
Doshita N, Ball J, Baum G, Berglund P, Gautheron F, Goertz S, Gustafsson K, Hasegawa T, Horikawa N, Ishimoto S, Iwata T, et al. (2004)
In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Nucl.Instrum.Meth. A, 526(1-2). Elsevier Science BV: 138-143.
Konferenzbeitrag
| Veröffentlicht | Englisch
Download
Es wurden keine Dateien hochgeladen. Nur Publikationsnachweis!
Autor*in
Doshita, N;
Ball, J;
Baum, GünterUniBi;
Berglund, P;
Gautheron, FabriceUniBi;
Goertz, S;
Gustafsson, K;
Hasegawa, T;
Horikawa, N;
Ishimoto, S;
Iwata, T;
Kisselev, Y
Alle
Alle
Einrichtung
Abstract / Bemerkung
The dynamic nuclear polarization (DNP) of (LiD)-Li-6 requires 1 mW/g or more microwave power in the beginning of the process. With the material of 350 g, this gives more than 350 mW in total for the COMPASS polarized target. A temperature around 300 mK or below is needed for an efficient polarization. These low temperatures can only be achieved with a dilution refrigerator designed to operate with a He-3 flow of 100 mmol/s. In order to keep the polarization in the frozen mode, temperatures of about 65 mK are used with typical magnetic relaxation times of more than 1400 h at 0.42 T and of more than 15 000 h at 2.5 T. Low lattice temperature is important in achieving high nuclear polarization. The base temperature is limited by the heat brought to the mixing chamber by the inlet 3 He and by radiation and conduction of heat. (C) 2004 Elsevier B.V. All rights reserved.
Stichworte
COMPASS;
cooling power;
dilution refrigerator;
polarized target
Erscheinungsjahr
2004
Titel des Konferenzbandes
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Serien- oder Zeitschriftentitel
Nucl.Instrum.Meth. A
Band
526
Ausgabe
1-2
Seite(n)
138-143
ISSN
0168-9002
Page URI
https://pub.uni-bielefeld.de/record/1607568
Zitieren
Doshita N, Ball J, Baum G, et al. Performance of the COMPASS polarized target dilution refrigerator. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Nucl.Instrum.Meth. A. Vol 526. Elsevier Science BV; 2004: 138-143.
Doshita, N., Ball, J., Baum, G., Berglund, P., Gautheron, F., Goertz, S., Gustafsson, K., et al. (2004). Performance of the COMPASS polarized target dilution refrigerator. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Nucl.Instrum.Meth. A, 526, 138-143. Elsevier Science BV. https://doi.org/10.1016/j.nima.2004.03.164
Doshita, N, Ball, J, Baum, Günter, Berglund, P, Gautheron, Fabrice, Goertz, S, Gustafsson, K, et al. 2004. “Performance of the COMPASS polarized target dilution refrigerator”. In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 526:138-143. Nucl.Instrum.Meth. A. Elsevier Science BV.
Doshita, N., Ball, J., Baum, G., Berglund, P., Gautheron, F., Goertz, S., Gustafsson, K., Hasegawa, T., Horikawa, N., Ishimoto, S., et al. (2004). “Performance of the COMPASS polarized target dilution refrigerator” in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Nucl.Instrum.Meth. A, vol. 526, (Elsevier Science BV), 138-143.
Doshita, N., et al., 2004. Performance of the COMPASS polarized target dilution refrigerator. In Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Nucl.Instrum.Meth. A. no.526 Elsevier Science BV, pp. 138-143.
N. Doshita, et al., “Performance of the COMPASS polarized target dilution refrigerator”, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Nucl.Instrum.Meth. A, vol. 526, Elsevier Science BV, 2004, pp.138-143.
Doshita, N., Ball, J., Baum, G., Berglund, P., Gautheron, F., Goertz, S., Gustafsson, K., Hasegawa, T., Horikawa, N., Ishimoto, S., Iwata, T., Kisselev, Y., Koivuniemi, J., Kondo, K., Matsuda, T., Meyer, W., Reicherz, G., Takabayashi, N.: Performance of the COMPASS polarized target dilution refrigerator. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Nucl.Instrum.Meth. A. 526, p. 138-143. Elsevier Science BV (2004).
Doshita, N, Ball, J, Baum, Günter, Berglund, P, Gautheron, Fabrice, Goertz, S, Gustafsson, K, Hasegawa, T, Horikawa, N, Ishimoto, S, Iwata, T, Kisselev, Y, Koivuniemi, J, Kondo, K, Matsuda, T, Meyer, W, Reicherz, G, and Takabayashi, N. “Performance of the COMPASS polarized target dilution refrigerator”. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Elsevier Science BV, 2004.Vol. 526. Nucl.Instrum.Meth. A. 138-143.
Export
Markieren/ Markierung löschen
Markierte Publikationen
Web of Science
Dieser Datensatz im Web of Science®Quellen
Inspire: 659336
Suchen in