Toward time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation
Wieland M, Spielmann C, Kleineberg U, Westerwalbesloh T, Heinzmann U, Wilhein T (2005)
ULTRAMICROSCOPY 102(2): 93-100.
Zeitschriftenaufsatz
| Veröffentlicht | Englisch
Download
Es wurden keine Dateien hochgeladen. Nur Publikationsnachweis!
Autor*in
Wieland, M;
Spielmann, C;
Kleineberg, U;
Westerwalbesloh, T;
Heinzmann, UlrichUniBi;
Wilhein, T
Einrichtung
Abstract / Bemerkung
Coherent soft X-ray sources open the way to new capabilities in high-resolution imaging, site- and element-specific spectroscopy and biomicroscopy. In this paper we demonstrate imaging with a table-top soft X-ray microscope. By combining a laser driven high-harmonic light source, optimized for having the maximum brightness at around 100 eV, a pair of multilayer mirrors to select a narrow spectral band and acting simultaneously as a condenser and a Fresnel zone plate as microscope objective, we were able to resolve 200 nm structures of a diatom sample. Further, the pulsed nature of our X-ray source offers the possibility of time-resolved spectromicroscopy with a temporal resolution in the order of a few femtoseconds. (C) 2004 Elsevier B.V. All rights reserved.
Stichworte
harmonic generation;
frequency conversion;
X-ray microscopes;
X-ray beams and X-ray optics
Erscheinungsjahr
2005
Zeitschriftentitel
ULTRAMICROSCOPY
Band
102
Ausgabe
2
Seite(n)
93-100
ISSN
0
Page URI
https://pub.uni-bielefeld.de/record/1605264
Zitieren
Wieland M, Spielmann C, Kleineberg U, Westerwalbesloh T, Heinzmann U, Wilhein T. Toward time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation. ULTRAMICROSCOPY. 2005;102(2):93-100.
Wieland, M., Spielmann, C., Kleineberg, U., Westerwalbesloh, T., Heinzmann, U., & Wilhein, T. (2005). Toward time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation. ULTRAMICROSCOPY, 102(2), 93-100. https://doi.org/10.1016/j.ultramic.2004.09-001
Wieland, M, Spielmann, C, Kleineberg, U, Westerwalbesloh, T, Heinzmann, Ulrich, and Wilhein, T. 2005. “Toward time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation”. ULTRAMICROSCOPY 102 (2): 93-100.
Wieland, M., Spielmann, C., Kleineberg, U., Westerwalbesloh, T., Heinzmann, U., and Wilhein, T. (2005). Toward time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation. ULTRAMICROSCOPY 102, 93-100.
Wieland, M., et al., 2005. Toward time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation. ULTRAMICROSCOPY, 102(2), p 93-100.
M. Wieland, et al., “Toward time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation”, ULTRAMICROSCOPY, vol. 102, 2005, pp. 93-100.
Wieland, M., Spielmann, C., Kleineberg, U., Westerwalbesloh, T., Heinzmann, U., Wilhein, T.: Toward time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation. ULTRAMICROSCOPY. 102, 93-100 (2005).
Wieland, M, Spielmann, C, Kleineberg, U, Westerwalbesloh, T, Heinzmann, Ulrich, and Wilhein, T. “Toward time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation”. ULTRAMICROSCOPY 102.2 (2005): 93-100.
Daten bereitgestellt von European Bioinformatics Institute (EBI)
15 Zitationen in Europe PMC
Daten bereitgestellt von Europe PubMed Central.
Development of a 10 kHz high harmonic source up to 140 eV photon energy for ultrafast time-, angle-, and phase-resolved photoelectron emission spectroscopy on solid targets.
Schmidt J, Guggenmos A, Chew SH, Gliserin A, Högner M, Kling MF, Zou J, Späth C, Kleineberg U., Rev Sci Instrum 88(8), 2017
PMID: 28863646
Schmidt J, Guggenmos A, Chew SH, Gliserin A, Högner M, Kling MF, Zou J, Späth C, Kleineberg U., Rev Sci Instrum 88(8), 2017
PMID: 28863646
Low chromatic Fresnel lens for broadband attosecond XUV pulse applications.
Pan H, Späth C, Guggenmos A, Chew SH, Schmidt J, Zhao QZ, Kleineberg U., Opt Express 24(15), 2016
PMID: 27464132
Pan H, Späth C, Guggenmos A, Chew SH, Schmidt J, Zhao QZ, Kleineberg U., Opt Express 24(15), 2016
PMID: 27464132
Effective increase in beam emittance by phase-space expansion using asymmetric Bragg diffraction.
Chu CH, Tang MT, Chang SL., Opt Express 23(17), 2015
PMID: 26368150
Chu CH, Tang MT, Chang SL., Opt Express 23(17), 2015
PMID: 26368150
Real-time and sub-wavelength ultrafast coherent diffraction imaging in the extreme ultraviolet.
Zürch M, Rothhardt J, Hädrich S, Demmler S, Krebs M, Limpert J, Tünnermann A, Guggenmos A, Kleineberg U, Spielmann C., Sci Rep 4(), 2014
PMID: 25483626
Zürch M, Rothhardt J, Hädrich S, Demmler S, Krebs M, Limpert J, Tünnermann A, Guggenmos A, Kleineberg U, Spielmann C., Sci Rep 4(), 2014
PMID: 25483626
Monochromatizing and focussing femtosecond high-order harmonic radiation with one optical element.
Ibek M, Leitner T, Erko A, Firsov A, Wernet P., Rev Sci Instrum 84(10), 2013
PMID: 24182096
Ibek M, Leitner T, Erko A, Firsov A, Wernet P., Rev Sci Instrum 84(10), 2013
PMID: 24182096
Improving high-order harmonic yield using wavefront-controlled ultrashort laser pulses.
Eyring S, Kern C, Zürch M, Spielmann C., Opt Express 20(5), 2012
PMID: 22418366
Eyring S, Kern C, Zürch M, Spielmann C., Opt Express 20(5), 2012
PMID: 22418366
A 50 nm spatial resolution EUV imaging-resolution dependence on object thickness and illumination bandwidth.
Wachulak PW, Bartnik A, Fiedorowicz H, Kostecki J., Opt Express 19(10), 2011
PMID: 21643212
Wachulak PW, Bartnik A, Fiedorowicz H, Kostecki J., Opt Express 19(10), 2011
PMID: 21643212
Femtosecond time-resolved photoelectron spectroscopy with a vacuum-ultraviolet photon source based on laser high-order harmonic generation.
Wernet P, Gaudin J, Godehusen K, Schwarzkopf O, Eberhardt W., Rev Sci Instrum 82(6), 2011
PMID: 21721681
Wernet P, Gaudin J, Godehusen K, Schwarzkopf O, Eberhardt W., Rev Sci Instrum 82(6), 2011
PMID: 21721681
Ultrahigh 22 nm resolution coherent diffractive imaging using a desktop 13 nm high harmonic source.
Seaberg MD, Adams DE, Townsend EL, Raymondson DA, Schlotter WF, Liu Y, Menoni CS, Rong L, Chen CC, Miao J, Kapteyn HC, Murnane MM., Opt Express 19(23), 2011
PMID: 22109124
Seaberg MD, Adams DE, Townsend EL, Raymondson DA, Schlotter WF, Liu Y, Menoni CS, Rong L, Chen CC, Miao J, Kapteyn HC, Murnane MM., Opt Express 19(23), 2011
PMID: 22109124
Sub-70 nm resolution tabletop microscopy at 13.8 nm using a compact laser-plasma EUV source.
Wachulak PW, Bartnik A, Fiedorowicz H., Opt Lett 35(14), 2010
PMID: 20634822
Wachulak PW, Bartnik A, Fiedorowicz H., Opt Lett 35(14), 2010
PMID: 20634822
Soft x-ray microscope constructed with a PMMA phase-reversal zone plate.
Park JJ, Kim DS, Jeon SC, Park J, Lee KH, Lee JH, Kim KN, Yoo JJ, Nam CH., Opt Lett 34(3), 2009
PMID: 19183616
Park JJ, Kim DS, Jeon SC, Park J, Lee KH, Lee JH, Kim KN, Yoo JJ, Nam CH., Opt Lett 34(3), 2009
PMID: 19183616
Tabletop soft-x-ray Fourier transform holography with 50 nm resolution.
Sandberg RL, Raymondson DA, La-O-Vorakiat C, Paul A, Raines KS, Miao J, Murnane MM, Kapteyn HC, Schlotter WF., Opt Lett 34(11), 2009
PMID: 19488126
Sandberg RL, Raymondson DA, La-O-Vorakiat C, Paul A, Raines KS, Miao J, Murnane MM, Kapteyn HC, Schlotter WF., Opt Lett 34(11), 2009
PMID: 19488126
Lensless diffractive imaging using tabletop coherent high-harmonic soft-X-ray beams.
Sandberg RL, Paul A, Raymondson DA, Hädrich S, Gaudiosi DM, Holtsnider J, Tobey RI, Cohen O, Murnane MM, Kapteyn HC, Song C, Miao J, Liu Y, Salmassi F., Phys Rev Lett 99(9), 2007
PMID: 17931040
Sandberg RL, Paul A, Raymondson DA, Hädrich S, Gaudiosi DM, Holtsnider J, Tobey RI, Cohen O, Murnane MM, Kapteyn HC, Song C, Miao J, Liu Y, Salmassi F., Phys Rev Lett 99(9), 2007
PMID: 17931040
Excited ions in intense femtosecond laser pulses: laser-induced recombination.
Williams ID, McKenna J, Wood J, Suresh M, Bryan WA, Stebbings SL, English EM, Calvert CR, Srigengan B, Divall EJ, Hooker CJ, Langley AJ, Newell WR., Phys Rev Lett 99(17), 2007
PMID: 17995325
Williams ID, McKenna J, Wood J, Suresh M, Bryan WA, Stebbings SL, English EM, Calvert CR, Srigengan B, Divall EJ, Hooker CJ, Langley AJ, Newell WR., Phys Rev Lett 99(17), 2007
PMID: 17995325
Sub-38 nm resolution tabletop microscopy with 13 nm wavelength laser light.
Vaschenko G, Brewer C, Brizuela F, Wang Y, Larotonda MA, Luther BM, Marconi MC, Rocca JJ, Menoni CS, Anderson EH, Chao W, Harteneck BD, Liddle JA, Liu Y, Attwood DT., Opt Lett 31(9), 2006
PMID: 16642063
Vaschenko G, Brewer C, Brizuela F, Wang Y, Larotonda MA, Luther BM, Marconi MC, Rocca JJ, Menoni CS, Anderson EH, Chao W, Harteneck BD, Liddle JA, Liu Y, Attwood DT., Opt Lett 31(9), 2006
PMID: 16642063
32 References
Daten bereitgestellt von Europe PubMed Central.
AUTHOR UNKNOWN, 0
Niemann, Opt. Commun. 12(), 1974
Denbeaux, Nucl. Instr. and Meth. A 72(5), 2001
Fischer, Rev. Sci. Instr. 72(), 2001
Attwood, 1999
Cryo X-ray microscopy with high spatial resolution in amplitude and phase contrast.
Schneider G., Ultramicroscopy 75(2), 1998
PMID: 9836467
Schneider G., Ultramicroscopy 75(2), 1998
PMID: 9836467
Jacobsen, Opt. Commun. 86(), 1991
Compact water-window transmission X-ray microscopy.
Berglund M, Rymell L, Peuker M, Wilhein T, Hertz HM., J Microsc 197(Pt 3), 2000
PMID: 10692130
Berglund M, Rymell L, Peuker M, Wilhein T, Hertz HM., J Microsc 197(Pt 3), 2000
PMID: 10692130
Johansson, Rev. Sci. Instr. 73(3), 2002
Generation of femtosecond pulses of synchrotron radiation
Schoenlein RW, Chattopadhyay S, Chong HH, Glover TE, Heimann PA, Shank CV, Zholents AA, Zolotorev MS., Science 287(5461), 2000
PMID: 10731140
Schoenlein RW, Chattopadhyay S, Chong HH, Glover TE, Heimann PA, Shank CV, Zholents AA, Zolotorev MS., Science 287(5461), 2000
PMID: 10731140
Beck, Opt. Commun. 190(), 2001
Nakano, Appl. Phys. Lett. 75(16), 1999
Attosecond Pulse Trains Using High-Order Harmonics.
Antoine P, L'Huillier A, Lewenstein M., Phys. Rev. Lett. 77(7), 1996
PMID: 10063025
Antoine P, L'Huillier A, Lewenstein M., Phys. Rev. Lett. 77(7), 1996
PMID: 10063025
Observation of a train of attosecond pulses from high harmonic generation.
Paul PM, Toma ES, Breger P, Mullot G, Auge F, Balcou P, Muller HG, Agostini P., Science 292(5522), 2001
PMID: 11387467
Paul PM, Toma ES, Breger P, Mullot G, Auge F, Balcou P, Muller HG, Agostini P., Science 292(5522), 2001
PMID: 11387467
X-ray pulses approaching the attosecond frontier.
Drescher M, Hentschel M, Kienberger R, Tempea G, Spielmann C, Reider GA, Corkum PB, Krausz F., Science 291(5510), 2001
PMID: 11239146
Drescher M, Hentschel M, Kienberger R, Tempea G, Spielmann C, Reider GA, Corkum PB, Krausz F., Science 291(5510), 2001
PMID: 11239146
Plasma perspective on strong field multiphoton ionization.
Corkum PB., Phys. Rev. Lett. 71(13), 1993
PMID: 10054556
Corkum PB., Phys. Rev. Lett. 71(13), 1993
PMID: 10054556
Chang, Phys. Rev. Lett. 79(16), 1997
Spielmann, Science 278(), 1997
Schnürer, Phys. Rev. Lett. 80(15), 1998
Wieland, Appl. Phys. Lett. 72(8), 2002
AUTHOR UNKNOWN, 0
AUTHOR UNKNOWN, 0
Generation of spatially coherent light at extreme ultraviolet wavelengths.
Bartels RA, Paul A, Green H, Kapteyn HC, Murnane MM, Backus S, Christov IP, Liu Y, Attwood D, Jacobsen C., Science 297(5580), 2002
PMID: 12130779
Bartels RA, Paul A, Green H, Kapteyn HC, Murnane MM, Backus S, Christov IP, Liu Y, Attwood D, Jacobsen C., Science 297(5580), 2002
PMID: 12130779
Attosecond metrology.
Hentschel M, Kienberger R, Spielmann C, Reider GA, Milosevic N, Brabec T, Corkum P, Heinzmann U, Drescher M, Krausz F., Nature 414(6863), 2001
PMID: 11734845
Hentschel M, Kienberger R, Spielmann C, Reider GA, Milosevic N, Brabec T, Corkum P, Heinzmann U, Drescher M, Krausz F., Nature 414(6863), 2001
PMID: 11734845
Steering attosecond electron wave packets with light.
Kienberger R, Hentschel M, Uiberacker M, Spielmann Ch, Kitzler M, Scrinzi A, Wieland M, Westerwalbesloh T, Kleineberg U, Heinzmann U, Drescher M, Krausz F., Science 297(5584), 2002
PMID: 12114530
Kienberger R, Hentschel M, Uiberacker M, Spielmann Ch, Kitzler M, Scrinzi A, Wieland M, Westerwalbesloh T, Kleineberg U, Heinzmann U, Drescher M, Krausz F., Science 297(5584), 2002
PMID: 12114530
Achromatic Fresnel optics for wideband extreme-ultraviolet and X-ray imaging.
Wang Y, Yun W, Jacobsen C., Nature 424(6944), 2003
PMID: 12840754
Wang Y, Yun W, Jacobsen C., Nature 424(6944), 2003
PMID: 12840754
Transmission microscropy of unmodified biological materials: comparative radiation dosages with electrons and ultrasoft x-ray photons.
Sayre D, Kirz J, Feder R, Kim DM, Spiller E., Ultramicroscopy 2(4), 1977
PMID: 919076
Sayre D, Kirz J, Feder R, Kim DM, Spiller E., Ultramicroscopy 2(4), 1977
PMID: 919076
Soft X-ray microscopy with a cryo scanning transmission X-ray microscope: I. Instrumentation, imaging and spectroscopy.
Maser J, Osanna A, Wang Y, Jacobsen C, Kirz J, Spector S, Winn B, Tennant D., J Microsc 197(Pt 1), 2000
PMID: 10620150
Maser J, Osanna A, Wang Y, Jacobsen C, Kirz J, Spector S, Winn B, Tennant D., J Microsc 197(Pt 1), 2000
PMID: 10620150
Tsilimis, Appl. Phys. A 76(), 2003
Quasi-phase-matched generation of coherent extreme-ultraviolet light.
Paul A, Bartels RA, Tobey R, Green H, Weiman S, Christov IP, Murnane MM, Kapteyn HC, Backus S., Nature 421(6918), 2003
PMID: 12511950
Paul A, Bartels RA, Tobey R, Green H, Weiman S, Christov IP, Murnane MM, Kapteyn HC, Backus S., Nature 421(6918), 2003
PMID: 12511950
Coherent soft x-ray generation in the water window with quasi-phase matching.
Gibson EA, Paul A, Wagner N, Tobey R, Gaudiosi D, Backus S, Christov IP, Aquila A, Gullikson EM, Attwood DT, Murnane MM, Kapteyn HC., Science 302(5642), 2003
PMID: 14526077
Gibson EA, Paul A, Wagner N, Tobey R, Gaudiosi D, Backus S, Christov IP, Aquila A, Gullikson EM, Attwood DT, Murnane MM, Kapteyn HC., Science 302(5642), 2003
PMID: 14526077
Time-resolved atomic inner-shell spectroscopy.
Drescher M, Hentschel M, Kienberger R, Uiberacker M, Yakovlev V, Scrinzi A, Westerwalbesloh T, Kleineberg U, Heinzmann U, Krausz F., Nature 419(6909), 2002
PMID: 12397349
Drescher M, Hentschel M, Kienberger R, Uiberacker M, Yakovlev V, Scrinzi A, Westerwalbesloh T, Kleineberg U, Heinzmann U, Krausz F., Nature 419(6909), 2002
PMID: 12397349
Export
Markieren/ Markierung löschen
Markierte Publikationen
Web of Science
Dieser Datensatz im Web of Science®Quellen
PMID: 15590132
PubMed | Europe PMC
Suchen in