Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy – high performance super-resolution at low cost

Diekmann R, Till K, Müller M, Simonis M, Schüttpelz M, Huser T (2017)
Scientific Reports 7(1): 14425.

Download
OA 4.86 MB
Zeitschriftenaufsatz | Veröffentlicht | Englisch
Volltext vorhanden für diesen Nachweis
Abstract / Bemerkung
Many commercial as well as custom-built fluorescence microscopes use scientific-grade cameras that represent a substantial share of the instrument’s cost. This holds particularly true for super-resolution localization microscopy where high demands are placed especially on the detector with respect to sensitivity, noise, and also image acquisition speed. Here, we present and carefully characterize an industry-grade CMOS camera as a cost-efficient alternative to commonly used scientific cameras. Direct experimental comparison of these two detector types shows widely similar performance for imaging by single molecule localization microscopy (SMLM). Furthermore, high image acquisition speeds are demonstrated for the CMOS detector by ultra-fast SMLM imaging.
Erscheinungsjahr
Zeitschriftentitel
Scientific Reports
Band
7
Zeitschriftennummer
1
Artikelnummer
14425
ISSN
Finanzierungs-Informationen
Article Processing Charge funded by the Deutsche Forschungsgemeinschaft and the Open Access Publication Fund of Bielefeld University.
PUB-ID

Zitieren

Diekmann R, Till K, Müller M, Simonis M, Schüttpelz M, Huser T. Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy – high performance super-resolution at low cost. Scientific Reports. 2017;7(1): 14425.
Diekmann, R., Till, K., Müller, M., Simonis, M., Schüttpelz, M., & Huser, T. (2017). Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy – high performance super-resolution at low cost. Scientific Reports, 7(1), 14425. doi:10.1038/s41598-017-14762-6
Diekmann, R., Till, K., Müller, M., Simonis, M., Schüttpelz, M., and Huser, T. (2017). Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy – high performance super-resolution at low cost. Scientific Reports 7:14425.
Diekmann, R., et al., 2017. Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy – high performance super-resolution at low cost. Scientific Reports, 7(1): 14425.
R. Diekmann, et al., “Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy – high performance super-resolution at low cost”, Scientific Reports, vol. 7, 2017, : 14425.
Diekmann, R., Till, K., Müller, M., Simonis, M., Schüttpelz, M., Huser, T.: Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy – high performance super-resolution at low cost. Scientific Reports. 7, : 14425 (2017).
Diekmann, Robin, Till, Katharina, Müller, Marcel, Simonis, Matthias, Schüttpelz, Mark, and Huser, Thomas. “Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy – high performance super-resolution at low cost”. Scientific Reports 7.1 (2017): 14425.
Alle Dateien verfügbar unter der/den folgenden Lizenz(en):
Copyright Statement:
This Item is protected by copyright and/or related rights. [...]
Volltext(e)
Access Level
OA Open Access
Zuletzt Hochgeladen
2018-01-17T15:03:14Z

50 References

Daten bereitgestellt von Europe PubMed Central.

Optimized localization analysis for single-molecule tracking and super-resolution microscopy.
Mortensen KI, Churchman LS, Spudich JA, Flyvbjerg H., Nat. Methods 7(5), 2010
PMID: 20364147
Super-resolution imaging of multiple cells by optimised flat-field epi-illumination.
Douglass KM, Sieben C, Archetti A, Lambert A, Manley S., Nat Photonics 10(11), 2016
PMID: 27818707
Chip-based wide field-of-view nanoscopy
Diekmann R., 2017

AUTHOR UNKNOWN, 0

AUTHOR UNKNOWN, 0
CCD Charge Collection Efficiency And The Photon Transfer Technique
Janesick J, Klaasen K, Elliot T., 1985

AUTHOR UNKNOWN, 0
easySTORM: a robust, lower-cost approach to localisation and TIRF microscopy.
Kwakwa K, Savell A, Davies T, Munro I, Parrinello S, Purbhoo MA, Dunsby C, Neil MA, French PM., J Biophotonics 9(9), 2016
PMID: 27592533
Quantitative evaluation of software packages for single-molecule localization microscopy.
Sage D, Kirshner H, Pengo T, Stuurman N, Min J, Manley S, Unser M., Nat. Methods 12(8), 2015
PMID: 26076424
ThunderSTORM: a comprehensive ImageJ plug-in for PALM and STORM data analysis and super-resolution imaging.
Ovesny M, Krizek P, Borkovec J, Svindrych Z, Hagen GM., Bioinformatics 30(16), 2014
PMID: 24771516
High-density three-dimensional localization microscopy across large volumes.
Legant WR, Shao L, Grimm JB, Brown TA, Milkie DE, Avants BB, Lavis LD, Betzig E., Nat. Methods 13(4), 2016
PMID: 26950745
Sample drift correction in 3D fluorescence photoactivation localization microscopy.
Mlodzianoski MJ, Schreiner JM, Callahan SP, Smolkova K, Dlaskova A, Santorova J, Jezek P, Bewersdorf J., Opt Express 19(16), 2011
PMID: 21934862
Precisely and accurately localizing single emitters in fluorescence microscopy.
Deschout H, Cella Zanacchi F, Mlodzianoski M, Diaspro A, Bewersdorf J, Hess ST, Braeckmans K., Nat. Methods 11(3), 2014
PMID: 24577276

AUTHOR UNKNOWN, 0

AUTHOR UNKNOWN, 0
A simple method to estimate the average localization precision of a single-molecule localization microscopy experiment.
Endesfelder U, Malkusch S, Fricke F, Heilemann M., Histochem. Cell Biol. 141(6), 2014
PMID: 24522395

AUTHOR UNKNOWN, 0
Measuring image resolution in optical nanoscopy.
Nieuwenhuizen RP, Lidke KA, Bates M, Puig DL, Grunwald D, Stallinga S, Rieger B., Nat. Methods 10(6), 2013
PMID: 23624665

AUTHOR UNKNOWN, 0
Ultrabright photoactivatable fluorophores created by reductive caging.
Vaughan JC, Jia S, Zhuang X., Nat. Methods 9(12), 2012
PMID: 23103881
Fiji: an open-source platform for biological-image analysis.
Schindelin J, Arganda-Carreras I, Frise E, Kaynig V, Longair M, Pietzsch T, Preibisch S, Rueden C, Saalfeld S, Schmid B, Tinevez JY, White DJ, Hartenstein V, Eliceiri K, Tomancak P, Cardona A., Nat. Methods 9(7), 2012
PMID: 22743772

Export

Markieren/ Markierung löschen
Markierte Publikationen

Open Data PUB

Web of Science

Dieser Datensatz im Web of Science®

Quellen

PMID: 29089524
PubMed | Europe PMC

Suchen in

Google Scholar