Background Off-pump coronary artery bypass grafting (OPCAB) has attracted increasing attention. Performing the anastomosis off-pump is technically more demanding. The objective of the study is to assess the quality of anastomosis in OPCAB in comparison with conventional on-pump coronary artery bypass grafting using the transit time flow measurement. Methods Four hundred forty-five patients operated on using OPCAB technique were included in the study. For each patient in this group a similar patient from the on-pump coronary artery bypass grafting population was selected according to the number of grafts, bypass material, and target coronary arteries. The mean flow and the pulsatile index were measured in every bypass graft in both groups. Results The average pulsatile index in OPCAB was 2.09 ± 1.03 (mean flow, 39 ± 22.63 mL/min), whereas with on-pump coronary artery bypass grafting it was 1.9 ± 0.98 (mean flow, 44.19 ± 23.58 mL/min); p = 0.005. Subgroup analysis showed significantly lower mean flows and higher pulsatile index with OPCAB in grafts to the obtuse marginal, diagonal, and right coronary artery, but not to the left anterior descending territory. Conclusions The quality of the anastomosis performed using the OPCAB technique might be jeopardized by less accessibility as in the case of lateral and posterior wall coronary arteries. Techniques to optimize the accessibility of the coronary artery like combining sling support with cup stabilizers, together with systematic training, should be strongly considered in OPCAB. Whenever there is good accessibility of the coronary artery as in the case of the left anterior descending, the anastomosis performed under OPCAB has a quality as good as that performed using the conventional technique.
Publishing Year
ISSN
PUB-ID

Cite this

Hassanein W, Albert AA, Arnrich B, et al. Intraoperative transit time flow measurement: off-pump versus on-pump coronary artery bypass. The annals of thoracic surgery. 2005;80(6):2155-2161.
Hassanein, W., Albert, A. A., Arnrich, B., Walter, J. A., Ennker, I. C., Rosendahlt, U. P., Bauer, S., et al. (2005). Intraoperative transit time flow measurement: off-pump versus on-pump coronary artery bypass. The annals of thoracic surgery, 80(6), 2155-2161.
Hassanein, W., Albert, A. A., Arnrich, B., Walter, J. A., Ennker, I. C., Rosendahlt, U. P., Bauer, S., and Ennker, J. (2005). Intraoperative transit time flow measurement: off-pump versus on-pump coronary artery bypass. The annals of thoracic surgery 80, 2155-2161.
Hassanein, W., et al., 2005. Intraoperative transit time flow measurement: off-pump versus on-pump coronary artery bypass. The annals of thoracic surgery, 80(6), p 2155-2161.
W. Hassanein, et al., “Intraoperative transit time flow measurement: off-pump versus on-pump coronary artery bypass”, The annals of thoracic surgery, vol. 80, 2005, pp. 2155-2161.
Hassanein, W., Albert, A.A., Arnrich, B., Walter, J.A., Ennker, I.C., Rosendahlt, U.P., Bauer, S., Ennker, J.: Intraoperative transit time flow measurement: off-pump versus on-pump coronary artery bypass. The annals of thoracic surgery. 80, 2155-2161 (2005).
Hassanein, W., Albert, Alexander A., Arnrich, Bert, Walter, Jörg A., Ennker, I.C., Rosendahlt, Ulrich P., Bauer, Stefan, and Ennker, Jürgen. “Intraoperative transit time flow measurement: off-pump versus on-pump coronary artery bypass”. The annals of thoracic surgery 80.6 (2005): 2155-2161.
This data publication is cited in the following publications:
This publication cites the following data publications:

9 Citations in Europe PMC

Data provided by Europe PubMed Central.

Intraoperative graft assessment during coronary artery bypass surgery.
Fukui T., Gen Thorac Cardiovasc Surg 63(3), 2015
PMID: 25556862
New device for intraoperative graft assessment: HyperEye charge-coupled device camera system.
Handa T, Katare RG, Nishimori H, Wariishi S, Fukutomi T, Yamamoto M, Sasaguri S, Sato T., Gen Thorac Cardiovasc Surg 58(2), 2010
PMID: 20155342
Intraoperative grafts assessment.
Leacche M, Balaguer JM, Byrne JG., Semin. Thorac. Cardiovasc. Surg. 21(3), 2009
PMID: 19942118
The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratio.
Balacumaraswami L, Abu-Omar Y, Selvanayagam J, Pigott D, Taggart DP., J. Thorac. Cardiovasc. Surg. 135(3), 2008
PMID: 18329465
Intraoperative imaging techniques to assess coronary artery bypass graft patency.
Balacumaraswami L, Taggart DP., Ann. Thorac. Surg. 83(6), 2007
PMID: 17532450
Graft-to-coronary-artery shunt during off-pump coronary artery bypass grafting.
Iida H, Mori H, Sudo Y, Yamada Y, Eda K, Inoue Y., Ann. Thorac. Surg. 82(3), 2006
PMID: 16928480
Invited commentary.
Mihaljevic T., Ann. Thorac. Surg. 80(6), 2005
PMID: 16305863

28 References

Data provided by Europe PubMed Central.

Seven-year follow-up of coronary artery bypasses performed with and without cardiopulmonary bypass.
Gundry SR, Romano MA, Shattuck OH, Razzouk AJ, Bailey LL., J. Thorac. Cardiovasc. Surg. 115(6), 1998
PMID: 9628668

AUTHOR UNKNOWN, 0

Export

0 Marked Publications

Open Data PUB

Web of Science

View record in Web of Science®

Sources

PMID: 16305862
PubMed | Europe PMC

Search this title in

Google Scholar