Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification

Büntemeyer H, Tebbe H, Lütkemeyer D, Lehmann J (1994)
Journal of Chromatography, B: Biomedical Sciences and Applications 662(2): 209-216.

Download
OA
Zeitschriftenaufsatz | Veröffentlicht | Englisch
Volltext vorhanden für diesen Nachweis
Autor
; ; ;
Abstract / Bemerkung
For monitoring of recombinant human antithrombin III during cell culture processes and subsequent purification steps a rapid method for quantitative determination was developed. The need for the introduction of this rapid method came from the limited availability of a quantitative enzyme-linked immunosorbent assay (ELISA) and the very time-consuming ELISA procedure. The developed method is based on reversed-phase high-performance liquid chromatography using a C 4 column. The separation by gradient elution using water and acetonitrile takes less than 20 min even when complex samples, such as serum containing cell culture samples, have to be analyzed. Automation and a high sample throughput are possible with this reliable method. If necessary, insulin, transferrin and albumin can also be quantified with minor changes of the elution profile.
Erscheinungsjahr
Zeitschriftentitel
Journal of Chromatography, B: Biomedical Sciences and Applications
Band
662
Zeitschriftennummer
2
Seite
209-216
ISSN
PUB-ID

Zitieren

Büntemeyer H, Tebbe H, Lütkemeyer D, Lehmann J. Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications. 1994;662(2):209-216.
Büntemeyer, H., Tebbe, H., Lütkemeyer, D., & Lehmann, J. (1994). Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications, 662(2), 209-216. doi:10.1016/0378-4347(94)00266-5
Büntemeyer, H., Tebbe, H., Lütkemeyer, D., and Lehmann, J. (1994). Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications 662, 209-216.
Büntemeyer, H., et al., 1994. Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications, 662(2), p 209-216.
H. Büntemeyer, et al., “Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification”, Journal of Chromatography, B: Biomedical Sciences and Applications, vol. 662, 1994, pp. 209-216.
Büntemeyer, H., Tebbe, H., Lütkemeyer, D., Lehmann, J.: Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification. Journal of Chromatography, B: Biomedical Sciences and Applications. 662, 209-216 (1994).
Büntemeyer, Heino, Tebbe, H., Lütkemeyer, Dirk, and Lehmann, Jürgen. “Rapid high-performance liquid chromatographic quantification of recombinant human antithrombin III during production and purification”. Journal of Chromatography, B: Biomedical Sciences and Applications 662.2 (1994): 209-216.
Alle Dateien verfügbar unter der/den folgenden Lizenz(en):
Copyright Statement:
This Item is protected by copyright and/or related rights. [...]
Volltext(e)
Access Level
OA Open Access
Zuletzt Hochgeladen
1970-01-01T00:00:00Z

Export

Markieren/ Markierung löschen
Markierte Publikationen

Open Data PUB

Web of Science

Dieser Datensatz im Web of Science®

Quellen

PMID: 7719477
PubMed | Europe PMC

Suchen in

Google Scholar