A large Streamer Chamber muon tracking detector in a high-flux fixed-target application

Adams D, Adeva B, Arik E, Arvidson A, Badelek B, Ballintijn MK, Bardin G, Baum G, Berglund P, Betev L, Bird IG, et al. (1999)
435(3): 354-374.

Download
Es wurde kein Volltext hochgeladen. Nur Publikationsnachweis!
Zeitschriftenaufsatz | Veröffentlicht | Englisch
Autor
; ; ; ; ; ; ; ; ; ; ;
Alle
Alternativer Titel
Nucl.Instrum.Meth. A
Abstract / Bemerkung
Arrays of limited streamer tubes of the Iarocci type were deployed in our experiment at CERN as part of a forward muon detector system with provisions for the beam to pass through the center of each panel in the array. A total of 16 4 m x 4 m panels were assembled with inductive readout strips on both sides of each panel. An active feedback system. was deployed to regulate the high voltage to the streamer tubes to insure a constant efficiency for minimum ionizing particles. The arrays were operated in this environment for over five years of data taking. Streamer tube track-reconstruction efficiencies and tube replacement rates are reported. (C) 1999 Elsevier Science B.V. All rights reserved.
Erscheinungsjahr
Band
435
Zeitschriftennummer
3
Seite
354-374
ISSN
PUB-ID

Zitieren

Adams D, Adeva B, Arik E, et al. A large Streamer Chamber muon tracking detector in a high-flux fixed-target application. 1999;435(3):354-374.
Adams, D., Adeva, B., Arik, E., Arvidson, A., Badelek, B., Ballintijn, M. K., Bardin, G., et al. (1999). A large Streamer Chamber muon tracking detector in a high-flux fixed-target application. 435(3), 354-374. doi:10.1016/S0168-9002(99)00556-2
Adams, D., Adeva, B., Arik, E., Arvidson, A., Badelek, B., Ballintijn, M. K., Bardin, G., Baum, G., Berglund, P., Betev, L., et al. (1999). A large Streamer Chamber muon tracking detector in a high-flux fixed-target application. 435, 354-374.
Adams, D., et al., 1999. A large Streamer Chamber muon tracking detector in a high-flux fixed-target application. , 435(3), p 354-374.
D. Adams, et al., “A large Streamer Chamber muon tracking detector in a high-flux fixed-target application”, vol. 435, 1999, pp. 354-374.
Adams, D., Adeva, B., Arik, E., Arvidson, A., Badelek, B., Ballintijn, M.K., Bardin, G., Baum, G., Berglund, P., Betev, L., Bird, I.G., Birsa, R., Bjorkholm, P., Bonner, B.E., de Botton, N., Boutemeur, M., Bradamante, F., Bravar, A., Bressan, A., Bultmann, S., Burtin, E., Cavata, C., Crabb, D., Cranshaw, J., Cuhadar, T., Dalla Torre, S., van Dantzig, R., Derro, B., Deshpande, A., Dhawan, S., Dulya, C., Dyring, A., Eichblatt, S., Faivre, J.C., Fasching, D., Feinstein, F., Fernandez, C., Forthmann, S., Frois, B., Gallas, A., Garabatos, C., Garzon, J.A., Gaussiran, T., Gilly, H., Giorgi, M., von Goeler, E., Goertz, S., Golutvin, I.A., Gomez-Tato, A., Gracia, G., de Groot, N., Perdekamp, M.G., Gulmez, E., Haft, K., von Harrach, D., Hasegawa, T., Hautle, P., Hayashi, N., Heusch, C.A., Horikawa, N., Hughes, V.W., Igo, G., Ishimoto, S., Iwata, T., Kabuss, E.M., Kageya, T., Karev, A., Kessler, H.J., Ketel, T.J., Kiryluk, J., Kiryushin, I., Kishi, A., Kisselev, Y., Klostermann, L., Kramer, D., Kroger, W., Kurek, K., Kyynarainen, J., Lamanna, M., Landgraf, U., Lau, K., Layda, T., Le Goff, J.M., Lehar, F., de Lesquen, A., Lichtenstadt, J., Lindqvist, T., Litmaath, M., Lowe, M., Magnon, A., Mallot, G.K., Marie, F., Martin, A., Martino, J., Matsuda, T., Mayes, B., McCarthy, J.S., Medved, K., Meyer, W., van Middelkoop, G., Miller, D., Miyachi, Y., Mori, K., Moromisato, J., Nassalski, J., Naumann, L., Niinikoski, T.O., Oberski, J.E.J., Ogawa, A., Ozben, C., Parks, D.P., Pereira, H., Penzo, A., Perrot-Kunne, F., Peshekhonov, D., Piegaia, R., Pinsky, L., Platchkov, S., Plo, M., Pose, D., Postma, H., Pretz, J., Pussieux, T., Pyrlik, J., Raadel, G., Reyhancan, I., Reicherz, G., Rijllart, A., Roberts, J.B., Rock, S., Rodriguez, M., Rondio, E., Ropelewski, L., Rosado, A., Roscherr, B., Sabo, I., Saborido, J., Sandacz, A., Sanders, D., Savin, I., Schiavon, P., Schiller, A., Schuler, K.P., Segel, R., Seitz, R., Semertzidis, Y., Sergeev, S., Sever, F., Shanahan, P., Sichtermann, E.P., Simeoni, F., Smirnov, G.I., Staude, A., Steinmetz, A., Stiegler, U., Stuhrmann, H., Szleper, M., Teichert, K.M., Tessarotto, F., Thers, D., Tlaczala, W., Trentalange, S., Tripet, A., Tzamouranis, I., Unel, G., Velasco, M., Vogt, J., Voss, R., Weinstein, R., Whitten, C., Willumeit, R., Windmolders, R., Wislicki, W., Witzmann, A., Zamiatin, N., Zanetti, A.M., Zaremba, K., Zhao, J.: A large Streamer Chamber muon tracking detector in a high-flux fixed-target application. 435, 354-374 (1999).
Adams, D, Adeva, B, Arik, E, Arvidson, A, Badelek, B, Ballintijn, MK, Bardin, G, Baum, Günter, Berglund, P, Betev, L, Bird, IG, Birsa, R, Bjorkholm, P, Bonner, BE, de Botton, N, Boutemeur, M, Bradamante, F, Bravar, A, Bressan, A, Bultmann, S, Burtin, E, Cavata, C, Crabb, D, Cranshaw, J, Cuhadar, T, Dalla Torre, S, van Dantzig, R, Derro, B, Deshpande, A, Dhawan, S, Dulya, C, Dyring, A, Eichblatt, S, Faivre, JC, Fasching, D, Feinstein, F, Fernandez, C, Forthmann, S, Frois, B, Gallas, A, Garabatos, C, Garzon, JA, Gaussiran, T, Gilly, H, Giorgi, M, von Goeler, E, Goertz, S, Golutvin, IA, Gomez-Tato, A, Gracia, G, de Groot, N, Perdekamp, MG, Gulmez, E, Haft, K, von Harrach, D, Hasegawa, T, Hautle, P, Hayashi, N, Heusch, CA, Horikawa, N, Hughes, VW, Igo, G, Ishimoto, S, Iwata, T, Kabuss, EM, Kageya, T, Karev, A, Kessler, HJ, Ketel, TJ, Kiryluk, J, Kiryushin, I, Kishi, A, Kisselev, Y, Klostermann, L, Kramer, D, Kroger, W, Kurek, K, Kyynarainen, J, Lamanna, M, Landgraf, U, Lau, K, Layda, T, Le Goff, JM, Lehar, F, de Lesquen, A, Lichtenstadt, J, Lindqvist, T, Litmaath, M, Lowe, M, Magnon, A, Mallot, GK, Marie, F, Martin, A, Martino, J, Matsuda, T, Mayes, B, McCarthy, JS, Medved, K, Meyer, W, van Middelkoop, G, Miller, David, Miyachi, Y, Mori, K, Moromisato, J, Nassalski, J, Naumann, L, Niinikoski, TO, Oberski, JEJ, Ogawa, A, Ozben, C, Parks, DP, Pereira, H, Penzo, A, Perrot-Kunne, F, Peshekhonov, D, Piegaia, R, Pinsky, L, Platchkov, S, Plo, M, Pose, D, Postma, H, Pretz, J, Pussieux, T, Pyrlik, J, Raadel, G, Reyhancan, I, Reicherz, G, Rijllart, A, Roberts, JB, Rock, S, Rodriguez, M, Rondio, E, Ropelewski, L, Rosado, A, Roscherr, B, Sabo, I, Saborido, J, Sandacz, A, Sanders, D, Savin, I, Schiavon, P, Schiller, A, Schuler, KP, Segel, R, Seitz, R, Semertzidis, Y, Sergeev, S, Sever, F, Shanahan, P, Sichtermann, EP, Simeoni, F, Smirnov, GI, Staude, A, Steinmetz, A, Stiegler, U, Stuhrmann, H, Szleper, M, Teichert, KM, Tessarotto, F, Thers, D, Tlaczala, W, Trentalange, S, Tripet, A, Tzamouranis, I, Unel, G, Velasco, M, Vogt, J, Voss, R, Weinstein, R, Whitten, C, Willumeit, R, Windmolders, R, Wislicki, W, Witzmann, A, Zamiatin, N, Zanetti, AM, Zaremba, K, and Zhao, J. “A large Streamer Chamber muon tracking detector in a high-flux fixed-target application”. 435.3 (1999): 354-374.

Export

Markieren/ Markierung löschen
Markierte Publikationen

Open Data PUB

Web of Science

Dieser Datensatz im Web of Science®

Quellen

Inspire: 496691

Suchen in

Google Scholar