Calibration of electrospray mass spectrometers with rccc-2,8,14,20-tetra-n-octyl-5,11,17,23-tetrahydroxyresorc[4]arene in the high mass range up to m/z 6000

Letzel M, Agena C, Mattay J (2001)
EUROPEAN JOURNAL OF MASS SPECTROMETRY 7(1): 35-38.

Journal Article | Published | English

No fulltext has been uploaded

Abstract
rccc-2,8,14,20-Tetra-n-octyl-5,11,17,23-tetrahydroxyresorc[4]arene has the property to form cluster ions in both positive- and negative-ion mode with good intensity without the addition of any modifiers such as cesium. These cluster ions may be used for the calibration of electrospray mass spectrometers in the mass range up to m/z 6000.
Publishing Year
ISSN
PUB-ID

Cite this

Letzel M, Agena C, Mattay J. Calibration of electrospray mass spectrometers with rccc-2,8,14,20-tetra-n-octyl-5,11,17,23-tetrahydroxyresorc[4]arene in the high mass range up to m/z 6000. EUROPEAN JOURNAL OF MASS SPECTROMETRY. 2001;7(1):35-38.
Letzel, M., Agena, C., & Mattay, J. (2001). Calibration of electrospray mass spectrometers with rccc-2,8,14,20-tetra-n-octyl-5,11,17,23-tetrahydroxyresorc[4]arene in the high mass range up to m/z 6000. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 7(1), 35-38.
Letzel, M., Agena, C., and Mattay, J. (2001). Calibration of electrospray mass spectrometers with rccc-2,8,14,20-tetra-n-octyl-5,11,17,23-tetrahydroxyresorc[4]arene in the high mass range up to m/z 6000. EUROPEAN JOURNAL OF MASS SPECTROMETRY 7, 35-38.
Letzel, M., Agena, C., & Mattay, J., 2001. Calibration of electrospray mass spectrometers with rccc-2,8,14,20-tetra-n-octyl-5,11,17,23-tetrahydroxyresorc[4]arene in the high mass range up to m/z 6000. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 7(1), p 35-38.
M. Letzel, C. Agena, and J. Mattay, “Calibration of electrospray mass spectrometers with rccc-2,8,14,20-tetra-n-octyl-5,11,17,23-tetrahydroxyresorc[4]arene in the high mass range up to m/z 6000”, EUROPEAN JOURNAL OF MASS SPECTROMETRY, vol. 7, 2001, pp. 35-38.
Letzel, M., Agena, C., Mattay, J.: Calibration of electrospray mass spectrometers with rccc-2,8,14,20-tetra-n-octyl-5,11,17,23-tetrahydroxyresorc[4]arene in the high mass range up to m/z 6000. EUROPEAN JOURNAL OF MASS SPECTROMETRY. 7, 35-38 (2001).
Letzel, Matthias, Agena, C, and Mattay, Jochen. “Calibration of electrospray mass spectrometers with rccc-2,8,14,20-tetra-n-octyl-5,11,17,23-tetrahydroxyresorc[4]arene in the high mass range up to m/z 6000”. EUROPEAN JOURNAL OF MASS SPECTROMETRY 7.1 (2001): 35-38.
This data publication is cited in the following publications:
This publication cites the following data publications:

Export

0 Marked Publications

Open Data PUB

Web of Science

View record in Web of Science®

Search this title in

Google Scholar