Performance of the COMPASS polarized target dilution refrigerator

Doshita N, Ball J, Baum G, Berglund P, Gautheron F, Goertz S, Gustafsson K, Hasegawa T, Horikawa N, Ishimoto S, Iwata T, et al. (2004)
Nucl.Instrum.Meth. A 526(1-2): 138-143.

Download
Es wurde kein Volltext hochgeladen. Nur Publikationsnachweis!
Konferenzbeitrag | Veröffentlicht | Englisch
Autor
; ; ; ; ; ; ; ; ; ; ;
Alle
Abstract / Bemerkung
The dynamic nuclear polarization (DNP) of (LiD)-Li-6 requires 1 mW/g or more microwave power in the beginning of the process. With the material of 350 g, this gives more than 350 mW in total for the COMPASS polarized target. A temperature around 300 mK or below is needed for an efficient polarization. These low temperatures can only be achieved with a dilution refrigerator designed to operate with a He-3 flow of 100 mmol/s. In order to keep the polarization in the frozen mode, temperatures of about 65 mK are used with typical magnetic relaxation times of more than 1400 h at 0.42 T and of more than 15 000 h at 2.5 T. Low lattice temperature is important in achieving high nuclear polarization. The base temperature is limited by the heat brought to the mixing chamber by the inlet 3 He and by radiation and conduction of heat. (C) 2004 Elsevier B.V. All rights reserved.
Erscheinungsjahr
Band
526
Zeitschriftennummer
1-2
Seite
138-143
ISSN
PUB-ID

Zitieren

Doshita N, Ball J, Baum G, et al. Performance of the COMPASS polarized target dilution refrigerator. Nucl.Instrum.Meth. A. 2004;526(1-2):138-143.
Doshita, N., Ball, J., Baum, G., Berglund, P., Gautheron, F., Goertz, S., Gustafsson, K., et al. (2004). Performance of the COMPASS polarized target dilution refrigerator. Nucl.Instrum.Meth. A, 526(1-2), 138-143. doi:10.1016/j.nima.2004.03.164
Doshita, N., Ball, J., Baum, G., Berglund, P., Gautheron, F., Goertz, S., Gustafsson, K., Hasegawa, T., Horikawa, N., Ishimoto, S., et al. (2004). Performance of the COMPASS polarized target dilution refrigerator. Nucl.Instrum.Meth. A 526, 138-143.
Doshita, N., et al., 2004. Performance of the COMPASS polarized target dilution refrigerator. Nucl.Instrum.Meth. A, 526(1-2), p 138-143.
N. Doshita, et al., “Performance of the COMPASS polarized target dilution refrigerator”, Nucl.Instrum.Meth. A, vol. 526, 2004, pp. 138-143.
Doshita, N., Ball, J., Baum, G., Berglund, P., Gautheron, F., Goertz, S., Gustafsson, K., Hasegawa, T., Horikawa, N., Ishimoto, S., Iwata, T., Kisselev, Y., Koivuniemi, J., Kondo, K., Matsuda, T., Meyer, W., Reicherz, G., Takabayashi, N.: Performance of the COMPASS polarized target dilution refrigerator. Nucl.Instrum.Meth. A. 526, 138-143 (2004).
Doshita, N, Ball, J, Baum, Günter, Berglund, P, Gautheron, Fabrice, Goertz, S, Gustafsson, K, Hasegawa, T, Horikawa, N, Ishimoto, S, Iwata, T, Kisselev, Y, Koivuniemi, J, Kondo, K, Matsuda, T, Meyer, W, Reicherz, G, and Takabayashi, N. “Performance of the COMPASS polarized target dilution refrigerator”. Nucl.Instrum.Meth. A 526.1-2 (2004): 138-143.

Export

Markieren/ Markierung löschen
Markierte Publikationen

Open Data PUB

Web of Science

Dieser Datensatz im Web of Science®

Quellen

Inspire: 659336

Suchen in

Google Scholar